⎝⎛真人博狗⎞⎠

无锡创想分析仪器有限公司

Stock Code: 202213

National unified free consultation hotline: 400-0833-980

Service Support

To first-class products
Quality service to meet customer needs

Location: ⎝⎛真人博狗⎞⎠ >> Service Support >>
Wuxi Chuangxiang Analysis Instrument Co., Ltd.

Domestic market department

0510-83205379 0510-66882099 13301511032

Ministry of International Trade

15106177808

Fax: 0510-83213469

E-mail: [email protected]

Address: No. 8 Chaoyang Road, South Zone, Hujing Industrial Park, Binhu District, Wuxi

Free consultation hotline:

400-0833-980

2020-02-21

Steps for cleaning the spark table by spectrometer

Excited samples, whether calibration samples or production samples, will produce black deposits in the spark table when excited, these deposits can lead ...

2020-02-17

Importance of direct reading spectrometer argon purity

Argon is a protective gas. In the analysis of the direct reading spectrometer, argon may be used in two places. After excitation, the material vaporizes, and some ...

2020-02-14

Method for eliminating black dots in direct reading spectrometer

After using a direct-reading spectrometer to excite the sample, the excitation point is dark and dark, and the following reasons are eliminated one by one to obtain a perfect point. The normal excitation idea should be: silvery white metallic luster in the middle ...

2020-02-13

Using method of argon purifier for direct reading spectrometer

The power supply voltage of the argon purifier for electric direct reading spectrometer is 220V. The voltage must be stable. It can be powered by a separate power supply or a stabilized power supply, but the stabilized power supply must also have a good voltage stabilization effect. Inside. ...

2020-02-12

What to do if the direct reading spectrometer element value is too low?

When the operator analyzes and finds that the overall data value is low, what should I do? Follow the steps below to eliminate the one by one and debug the spectrometer ...

2020-02-11

Calibration sequence of direct reading spectrometer

Calibration of direct reading spectrometer instruments should start with hardware and then software. The direct reading spectrometer is calibrated as follows: Trace is the calibration of the optical system of the spectrometer ...

2020-01-13

The role of X-ray fluorescence spectrometer lines

X-rays were originally used in medical imaging diagnostics and X-ray crystallography, and they are also very useful in analytical instruments. This is due to the high ability of X-rays to penetrate through many substances that are opaque to visible light, ...

2020-01-10

Spectral incident light path structure of direct reading spectrometer

Incident light path of direct-reading spectrometer The incident light path of direct-reading spectrometer refers to that the spectrometer emits all the spectral luminous fluxes excited by the light source into the concave grating in the optical room during the exposure phase. In concave light ...

2020-01-09

Pros and cons of direct-reading spectrometer grinding prototypes and milling machines

Spectral grinding sample machine is a device for polishing spectroscopic samples in the process of preparing spectroscopic samples. Specimens polished by a spectrometer can obtain a mirror-like surface, which is more conducive to accurate spectral analysis. ...

1 2 3 4 5 6 7 8 9 10 ... 38 39 » « 1 2 3 4 5 6 7 8 9 10 ... 38 39 »


苏ICP备16025720号全国统一免费咨询服务热线400-0833-980地址:江苏省无锡市滨湖区胡埭工业园南区富润路8号 -Copyright : Wuxi Chuangxiang Analytical Instrument Co., Ltd. Su ICP No. 16025720 National Unified Free Consultation Service Hotline 400-0833-980 Address: No. 8 Furun Road, South District, Hujing Industrial Park, Binhu District, Wuxi City, Jiangsu Province
Copyright copy; 2015 gxcxe.com studio All Rights Reserved-
七乐彩 欢乐拼三张 真人游戏平台注册 必赢真人娱乐