Find out whether the curve of direct reading spectrometer is good or bad

Release time: 2020-01-08 11:59:39 Click: 645

一直在拉近 The direct-reading spectrometer appeared late, but because of its advantages of full-element analysis, many domestic manufacturers need this instrument for analysis. This technology has been getting closer from abroad to China . 年,国外开始出现 CCD 全谱直读光谱仪, 08 年国内开始有厂家试产基于 CCD 的全谱分析仪器。 In 2000 , CCD full-spectrum direct-reading spectrometers began to appear abroad . In 2008 , domestic manufacturers began trial production of CCD- based full-spectrum analysis instruments. 8 年的差距。 At this point, there is only a gap of 8 years between the spectrometer technology at home and abroad .

探寻直读光谱仪制作曲线好坏

Find out whether the curve of direct reading spectrometer is good or bad

There are many reasons why direct-reading spectrometers produced by different manufacturers are different. The quality of the devices is good. Many domestic devices of analytical instruments cannot be replaced because of technical difficulties. Many of the core devices still need to use foreign devices. CMOS 的时代,非常短暂,目前很多企业都在转向 CMOS 的直读光谱仪的研究。 However , the era from the prevalence of CCD to CMOS is very short. At present, many companies are turning to the research of CMOS direct reading spectrometer.

After the working curve is completed, the difference between the measured value and the true value of the standard sample of the working curve, the smaller the deviation, the success of the working curve is proved.

x 荧光、ICP不同,不需要本人动手去扣除干扰和背景,仪器在厂家预制曲线的时候,已经把干扰、背景等影响因素通过干扰校正系数进行扣除了。 In addition to the quality of the device, direct reading is different from x- fluorescence and ICP. I do not need to manually deduct interference and background. When the instrument prefabricates the curve, the interference and background factors have been deducted through the interference correction coefficient. If you want to know what elements interfere with which elements, you can check them in the setting parameters of the instrument.Its coefficients are all empirical coefficients, which are derived from a large amount of experimental data . These experimental data are also the foundation of analytical instrument companies. They are piled up with countless standard samples and tests. Many times manufacturers know how to debug the instruments.
The maintenance of the direct reading spectrometer is actually very simple. It cleans the impurities generated by multiple excitations so that they do not affect the test. 2. 清理火花台; 3. 更换电极; 4. 擦拭透镜或石英窗。 1. Change argon; 2. Clean the spark table; 3. Replace the electrode; 4. Wipe the lens or quartz window. 偶遇长时间停电。 5. Encounter a long power outage. , 做一下描迹 , 然后再做曲线 , 注意选用合适的标准化试样 , 这样做出来的曲线应该没有问题 , 如果线性很好 , 但有系统偏差的话 , 可以通过修正系数达到好的效果 .Before making the curve, you should thoroughly clean the instrument excitation table, etc. , make a trace , and then make the curve , pay attention to selecting a suitable standardized sample , the curve obtained in this way should be no problem , if the linearity is very good , but there is a systematic deviation , You can achieve good results through the correction factor .

The above can achieve relatively good results and obtain a direct reading spectrometer curve with good effect.

Previous: What does the optical resolution of the spectrometer determine? Next: Advantages and Disadvantages of Direct Reading Spectrometer Grinding Machine and Milling Machine

hot key words:

Direct Reading Spectrometer

High frequency infrared carbon and sulfur analyzer

Spark Direct Reading Spectrometer

Portable spectrometer

Photoelectric Direct Reading Spectrum Analyzer


苏ICP备16025720号全国统一免费咨询服务热线400-0833-980地址:江苏省无锡市滨湖区胡埭工业园南区富润路8号 -Copyright : Wuxi Chuangxiang Analytical Instrument Co., Ltd. Su ICP No. 16025720 No. 400-0833-980, the national unified free consultation service hotline Address: No. 8, Furun Road, South District, Hudai Industrial Park, Binhu District, Wuxi City, Jiangsu Province
Copyright copy; 2015 gxcxe.com studio All Rights Reserved-
七乐彩 欢乐拼三张 真人游戏平台注册 必赢真人娱乐