Mutual restriction of three parameters of spectrometer

Release time: 2020-01-03 09:25:31 Click: 451

In addition to the resolution of the spectrometer detector, an important factor to consider, the size of the active area and the count rate are also important. In practical applications, the energy detection range, resolution, effective active area of the detector, corresponding linear range, and beryllium window thickness are important factors to consider when selecting a detector.

In fact, the three factors of resolution, effective active area, and linear corresponding range are just mutually restricted. The preamp noise is mainly determined by the pulse shaping time constant, and the relationship between the energy resolution and the pulse shaping time constant shows a minimum value. The curve distribution, so sometimes a slightly larger pulse forming time constant is appropriately selected, which can have higher energy resolution, but the linear analysis range may be affected. When a narrow pulse width is required to maintain high count rate blood, a detector with a smaller pulse shaping time constant can be selected. The shorter the spectral peak forming time of the detector, the wider the linear corresponding range, but the lower the resolution of the detector. 20 40 cps ,分辨率为 250ev ,尽管谱峰成型时间为 25.6 微妙的探测器,其线性相应范围只有约为 1 万~ 1.5 cps, 但分辨率则提高到优于 15DeV, 如图 4-9 所示。 For example, the linear corresponding range of the peak forming time is about 200,000 to 400,000 cps , and the resolution is 250ev . Although the spectral peak forming time is 25.6 subtle detectors, the linear corresponding range is only about 10,000 to 15,000 cps. But the resolution is improved to better than 15DeV, as shown in Figure 4-9 . The smaller the area of the detector, the longer the peak shape time and the higher the resolution. The larger the area, the worse the resolution. Therefore, when a high counting rate is required, usually only a large area detector can be used.

光谱仪三种参数的相互制约

Mutual restriction of three parameters of spectrometer

The thickness of the beryllium window is another important point to consider when selecting a detector. 4 20 所示,采用 2m 的铍窗,将很难定 Na 等轻元素。 Due to the strong absorption of the light element analysis line by the tweezers, its detection efficiency is very low. As shown in Figure 4-20 , using a 2m beryllium window will make it difficult to determine light elements such as Na . Therefore, for the analysis of light elements, of course, the thinner the beryllium window is, the better. But too thin beryllium window thickness will also affect its service life. Therefore, when choosing the thickness of the beryllium window, a suitable beryllium window thickness detector should be determined according to the object to be analyzed. If there is no actual demand, it is not necessary to excessively pursue a thin beryllium window.

X 射线荧光分析而言,通常的探测器厚度已满足需求,如果需要分析重元素的 K 系谱线或高能粒子,探测器厚度也是需要重视的一个环节。 In addition, for conventional X -ray fluorescence analysis, the thickness of the usual detector has met the requirements. If K- line or high-energy particles of heavy elements need to be analyzed , the thickness of the detector is also a link that needs attention. The greater the thickness of the detector. The more beneficial it is to analyze high-energy particles or high-energy rays. When choosing an energy detector, it is necessary to consider the resolution of the detector on the one hand, and also to consider the determination of the main element as the focus of the analysis, in order to find the widest concentration measurement range, or the good resolution. Rate and emphasis on trace element analysis. Synthesis and compromise are probably the usual choices.

In short, when selecting a detector, the resolution, linear response range, beryllium window thickness, detector thickness, and effective detection area should be comprehensively considered according to the object to be analyzed, and the analysis scope of primary, secondary, and trace elements should be weighed, with some emphasis. In order to effectively meet the purpose of most analysis projects.

下一篇: 学会看直读光谱仪生成图的坐标 Previous: Comparison of Three Common X-ray Spectrometer Detectors Next: Learn to See the Coordinates Generated by Direct Reading Spectrometer

hot key words:

Direct Reading Spectrometer

High frequency infrared carbon and sulfur analyzer

Spark direct reading spectrometer

Portable spectrometer

Photoelectric direct reading spectrum analyzer


苏ICP备16025720号全国统一免费咨询服务热线400-0833-980地址:江苏省无锡市滨湖区胡埭工业园南区富润路8号 -Copyright : Wuxi Chuangxiang Analytical Instrument Co., Ltd. Su ICP No. 16025720 National Unified Free Consultation Service Hotline 400-0833-980 Address: No. 8 Furun Road, South District, Hujing Industrial Park, Binhu District, Wuxi City, Jiangsu Province
Copyright copy; 2015 gxcxe.com studio All Rights Reserved-
七乐彩 欢乐拼三张 真人游戏平台注册 必赢真人娱乐